> Replace the bad outer door, & defective gas control valve/ thermostat. Your water heaters control knob will not turn off or move to the pilot position if it is stuck in the On position. There is no particular reset button on your Honeywell water heater digital thermostat. Next up, you need to make sure that the water heater is getting the correct voltage. First up, check the thermostat of the heater and replace the defective one. Step #3: While holding the knob, press the piezo igniter button at the same time. So, keep reading between the lines. Aside from lighting the gas burner, the pilot also heats the thermocouple, which creates a small amount of electricity to hold the electromagnetic valve open inside of the gas control valve. When yourHoneywell water heater pilot light wont light, your heater will stop heating. Heater Not Heating 6. What are the symptoms of a broken water heater? You can order parts online like on Home Depot or on Amazon. If the thermocouple is reading less than 25 millivolts, then it is bad. The sediment contains different chemicals and salt. Just follow the below simple steps I described below to make the replacement correctly: First off, turn the main gas supply valve clockwise to stop the gas supply to the unit. The furnace gas valve for this type of furnace is identifiable with its solenoid designations: MV (main valve), PV (pilot valve), and PV/MV (common). For safety reasons, you should make sure that the gas is turned to the off position when you are doing any work to the water heater. Blocked vents or insufficient air supply. Get free, zero-commitment quotes from pro contractors near you. Finally, verify the igniter is working properly by relighting the pilot following the lighting instructions on the manual. If the igniter fails, the burner will not light. When this happens, your burners wont ignite and your homes water will be freezing cold. Make sure that the power of the water heater is turned on. A defective thermostat can be changed by professionals to overcome this problem. Or from your water heaters front, the water can leak. It will ensure a fluent gas flow. Unfortunately, working on a hot water heater is usually something that is going to require a professional. You will know it is working if you feel the heat coming from the unit. What does blue light on the Honeywell water heater mean? Due to a loose connection of the connector, the red status light will not blink. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Honeywell Water Heater Leaking 11. Note: You can also read how to fix Honeywell hot water heater status light blinking 7 times. Heater Knob Stuck 10. Turn it off at the breaker panel and then on to the heat setting. 2 - Replace Pilot Assembly Insufficient power to the gas control valve/thermostat. I believe it is 9 years old as the date on the label says 2011. i think i need to change the burner assembly coz when i took it off, i couldn't get a spark in the igniter when it is connected. Step 8. The procedure for properly lighting a pilot light will vary based on the water heater you have. Ensure the drain valve is unclogged and working fluently. > Ensure all the snug electrical connections to the gas control valve. If needed, rub the connection with sandpaper. There is more than one type of electronic ignition water heater. link to How To Organize A Bathroom Closet. Replace the defective one. You need to replace the bent or damaged electrode with the help of a qualified contractor. Turning the knob will change the water temperature in the tank. So, whenever you start to struggle with any issue with your heater, just follow our Honeywell water heater troubleshooting guide and fix it by yourself. Take a deep breath, and lets start with some of the basics. Honeywell Ignitor - How to Replace a Water Heater Ignitor FIX IT Home Improvement Channel 98.1K subscribers Subscribe 213 65K views 8 years ago Subscribe and visit our weekly FIX IT Home. Lets look at some of the most common problems, so that we may find the solutions. It also implies RAM loaded over 90% and the battery life reduced to 15% or less. Each of them indicates different problems. Now look for any soot build-up in the pilot light tube that is preventing the pilot light from lighting. If yes, release the valve and set the knob to your desired temperature setting. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Anything that uses gas, needs to be worked on by someone who is licensed. If the flames color is red, yellow, green, or anything other than bright blue, this means that something else is inside of the gas and is burning along with the methane. Honeywell Water Heater Igniter Not Working, 7. In most cases, the status light doesnt blink due to inadequate air supply. You will need to use your multimeter to test it. When all is done, the status should start blinking. Another possibility is that there is something blocking the igniters contact with the wire coil in the furnace. When this component gets damaged by corrosion or bent, it wont function anymore. COPYRIGHT 2023. Look through the igniter viewpoint and inspect whether it sparks or not. Does the Honeywell thermostat have a reset button? Repair the damaged part as soon as possible. You will need to replace the thermocouple at this point. If your water heater is beeping due to overheating, turn the thermostat down to reduce the temperature. Consequently, the pilot wont light and the status light will not blink. This leaves you with two possible solutions. Here are the needed steps to resolve this connection issue: First up, locate the gas control valve. So, you should replace it after every 7 years. The pilot lights the gas burner for the water heater. If the igniter wires come loose from their connector, the controller will receive no signal for ignition. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Upvote Lets start: The Honeywell heater users often complain about a major problem: the Honeywell water heater keeps turning off or wont stay lit. Then, click on the igniter multiple times and look for a spark. Save my name, email, and website in this browser for the next time I comment. If I understand correctly, your pilot flame is lighting correctly. How do I know if my water heater is working? Unclog the heater vents and air intake. Continuously thermopile generates electric power while the gas valve/temperature knob is turned off. When you have a problem with your water heater, you will need to do some troubleshooting and some testing. However, if this method fails, you might have to replace it altogether in order to provide sufficient heat throughout your home during these frigid winter nights. Any of these can be the reason behind the issue. how to fix Honeywell water heater sensor failure, How to Reset Honeywell Thermostat? Step #5: Keep holding the knob untilthe maximum voltage is reached. Move the brush back and forth and clean the base area properly. Still, if the knob remains in the same position, you should do the following: Note: Dont use any oil to fix the stuck knob. How Long For A Water Heater To Heat After A Reset? Then properly clean it, Ensure your heater is getting an adequate gas supply, Air in the gas line or insufficient air supply, Replace the malfunctioning thermopile, bad gas control valve and its lousy wiring, tripping thermal switch, & stuck gas control knob, Tighten the gas control valves wiring connection, Clean the gas lines air and ensure the sufficient air supply. I see absolutely nothing inside the little window on the hot water heater. Burner Will Not Ignite 8. It may be rust, oil, grime, dirt, or excess air in the system. Then, check and replace the bad gas control valve. Start with inspecting the igniter wire (its either white or orange). The most common. A typical issue with a thermostat is that it may be over-saturated or dirty and not working effectively. Pilot lights, but the main burner doesn't come on. If the thermostat is not set at a comfortable temperature, adjust it to the correct setting. 12. Honeywell Water Heater Control Not Working. Follow the solutions below and make sure your Honeywell heaters status light is blinking. In this stage, what you need to do is to take everything out that leads into the gas control valve. The pilot ignites the gas burner on your water heater. If the water line is connected properly, check to see if theres an obstruction in the water line itself. When you click the igniter, you should hear a click sound, indicating the spark igniting the pilot. Make sure the white igniter is snugly inserted into the white or orange connector. Or reset your water heater. Throughout this article, we have assembled all the aspects behind the Honeywell water heater status light not blinking issue. Its essential to regularly clean your water filter to avoid this issue, and if you find that its already clogged, youll need to replace it. Click to reveal If your electronic ignition water heater, will not light, then it could be a loose wire, the ignition may not be getting the correct voltage, or you may just need to try lighting it more than once. After resolving the pilot issue and there is still no blinking on the status light, a bad igniter or malfunctions from the igniter is the second suspect. After that, switch to hot for 10 seconds and to pilot for 10 seconds. how to fix Honeywell hot water heater status light blinking 7 times, solution guide in the hot water heater pilot wont light section of the article, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. We and our partners use cookies to Store and/or access information on a device. If you determine that it has the correct voltage, then you will need to move on to the next possible issue. As a result, the igniter fails to ignite the burner. There are several factors for continuously tripping the thermal switch. Step #2: After that time, set the control knob to the pilot position. Easy things, you will be able to work on yourself. If it is flowing, measure the voltage between the 24V Hot and 24V Common leads to the SmartValve. After going through our ultimate guide, already you know what are the common Honeywell water heater problems, their reason, and solutions. If still, there is no spark, inspect the spark electrode visually. Take a pressure gauge and measure the gas pressure. > Replace the bad gas control valve, & thermostat. This issue is most likely caused by one of the following: If your gas water heater has an electronic ignition system, you should never attempt to light it by hand. The control board will throw a code if there is a problem with the voltage. You have to define the errors depending on the number of blinking. Turn off the gas supply valve to your appliance to test whether your valve is capable of shutting down properly. We need them to do laundry, take showers, clean dishes, and much more. A damaged thermocouple could be the next problem on the list. Weve also outlined some other common water heater pilot light problems and how to fix them. Take the help of an electrician to repair the damaged wiring issue. When your Honeywell heater stops heating, you should check the pilot light first. Being a Los Angeles resident, Jessica spends a lot of her time looking for her next DIY project and sharing her love for home design. Press the button firmly. All Right Reserved by FIREPLACEHUBS. An induced draft water heater is a type of water heater that uses a small fan, to draw the combustion gas from the combustion chamber. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. 4 Flashes = Temperature Exceeded. Using your manual, enter the thermostat configuration and change the system type setting and re-attempt to call for heat/ return to step 1. Ensure each of the heating elements is blockage free. Bathroom closets are often catch-alls for anything and everything remotely related to self-care. Also, testing the thermopile reading is a must to ensure that it really needs replacement. Anyway, from this article, you are getting the complete solutions guide related to the status light no blinking issue. Replacing an igniter on Honeywell Water Heater is just a piece of cake. Another possibility behind the malfunctioning of the control system includes: If your Honeywell water heater is not turning on, it may be because of a problem with the electrical system. Weve put together this guide to help you find the solution. > Replace lousy thermostat, & faulty gas control valve turned off the thermostat/control valve. Either the pilot light is going out, or the pilot light is failing to start. If the status light doesnt start blinking after 90 seconds of starting your heater, you should take it seriously. Other reasons for this problem are: There are a few possible causes for a malfunctioning Honeywell water heater igniter. Whether your water heater is running or not, in some water heaters, the pilot light is always burning while using a minute amount of gas. Finally, follow the steps in reverse to complete the burner assembly installation. Clean the clogged valve. Your Honeywell water heaters faulty gas valve will lead to different problems. Why Is Honeywell Water Heater Status Light Not Blinking? > Verify the whiter igniter is firmly inserted into the white or orange connector. Manage Settings However, the other solutions are: Your Honeywell water heater can make noise or sizzling sounds due to internal condensation. Jessica considers herself a home improvement and design enthusiast. Performance & security by Cloudflare. How do you light a hot water heater with an igniter Honeywell? Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Some people refer to this problem as a flare out or simply pilot failure. Honeywell Water Heater Sensor Failure [5 Easy Fixes], Why Duraflame Heater Flame Not Working [Reasons + Solutions], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix], > LED is not lit, or the thermopile didnt get the normal temperature yet. | Is It Dangerous For The Water Heater Pilot Light To Go Out? There are several reasons behind the no blink on the Honeywell Status light. Eric,your tutorial was very helpful, Im from El Paso as well. Bad thermopile or defective igniter are the two main culprits that cause the status light to not blink. A faulty igniter will fail to glow even after receiving an adequate amount of voltage. Improper installation of the spark rod and the pilot head. This website is using a security service to protect itself from online attacks. Continue with Recommended Cookies. Chances are there may be an easy fix or a fix that you can do yourself, without calling in a plumber. You will find a small reset button in the center of the thermal switch. This makes the pilot flame small and unsustainable. Faulty Gas Control Valve's Electrical Connections 5. As I mentioned earlier, three culprits: loose igniter wiring, dirty thermopile, and bad igniter cause the igniter to not work. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. Blow out the accumulated dirt from the spark button with compressed air. Clogged base-ring filters or the flame arrestor> Clean out base-ring filters & the flame arrestor with the brush-attached vacuum cleaner. If the main control valve is bad, your water heater igniter will not be able to light the pilot, no matter how many times you try. Step #4: Then, relight the pilot andhold down the gas controls thermostat knob once it is light. That's why you should inspect these two elements first and repair or replace them to let the status light blink again. Change the defective elements of the system to prevent this problem. When you click on the igniter, there should be a tiny spark happening inside of the pilot. The first option is to clear out and remove any deposits from the pilot, ensuring that it can ignite easily and early enough to light your boilers gas before it runs out of air. If youre having trouble getting your water heater to light its pilot light, first check the following spark electrode for dirt and corrosion since this could be your problem. All Right Reserved by FIREPLACEHUBS. After following this well-proven guide, hopefully, you will not face single trouble while resolving this issue. Thank for your feedback. Verify the water pipes are properly insulated and ventilated. You will need to know whether your hot water heater uses an intermittent pilot, or a hot surface ignition so that you can properly address the issues with the igniter. Typically, an igniter on a water heater lasts around 7 to 15 years. First up, check all the pipe connections of the water heater. If there is no spark, be sure it is not getting the voltage. Honeywell Water Heater Is Not Hot Enough, 3. If the issue is related to only the pilot and igniter, simply cleaning and replacing the defective parts can resolve the problem. How do I reset my Honeywell water heater? That way, the gas can flow easily. Heater Overheating 9. Here you go: First up, turn off the power to your water heater. You can check the state of the igniter by inspecting if it is receiving voltage. Go on reading our Honeywell water heater troubleshooting guide. Basically,thermopile in an open circuit test reads 650 to 850 millivolts. One of the most common problems that can develop in older Honeywell water heaters is something referred to as a pilot light going out. Induced draft water heaters use an intermittent pilot or hot surface ignition instead of a standing pilot light. Position the lighter over the end of the pipe by the burner. Sometimes due to low fuel, the heater may start beeping. However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot. Make sure you have a set of screwdrivers, a socket set, and a multimeter. You need to replace the damaged or faulty FV sensor when it doesnt get out of the lockout mode even after resetting it. If your pilot light still wont stay lit, the issue is almost always caused by a defective thermocouple. I live on the Eastside and went to Eastwood High back in the day. The only way for you to troubleshoot your main control valve is to rule out all of the other issues on our list of common problems. Your heaters burner fails to ignite mainly for the following factors: For fixing the above difficulties, the easy resolving ways are: Honeywell water heater overheatingis one of the potentially dangerous issues with your gas water heater. Check for gas leaks. Also, connect the black lead to the white wire. Due to inadequate gas, your heater fails to ignite and heat the water. Water heaters are not appliances that are relatively safe to work with. Use your multimeter, to test how much voltage is going to the igniter. Also, this guide has the solutions to other hitches like the heater not heating, overheating; the burner wont ignite, error codes, etc. If your heaters status light wont blink, turn off the gas valve and release the gas control knob. However, if you have any more struggles with any other issues with your heater, dont hesitate to let us know in the comment box. Here you go: To test the thermopile, you just needa multi-meter to read the millivolts. So, throughout this above Honeywell water heater troubleshooting guide, we well-explained all the major hitches and their solutions. To solve this problem, use a wire brush to remove any dirt or corrosion from the inside circuit at the top of the water heater tank and try lighting it again. What if the Honeywell water heater light not blinking? if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-netboard-1','ezslot_24',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-netboard-1-0');A thermal switch is a safety device on a water heater. We will tell you all the reasons behind each issue with their simple solutions. 575K views 8 years ago AO Smith Gas Water Heater This video provides step-by-step instructions for replacing the igniter and flame sensor on AO Smith gas water heaters. Can you replace an igniter on a gas water heater? Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. Now, light the pilot using the instructions and check the status light. Whether it be identifying the problem or replacing a part, lets take a look at what you should do when your water heater igniter wont spark. But they usually have a manual adjustment knob on the front. Next, remove a screw from the bottom of the Honeywell Gas Control Valve. Also, make sure that every heating element is in good working condition. Step #2: Disconnect thewiring connector of the thermopile from the gas control. The stuck knob may cause your heater to overheat also. The below table will provide you with a clear idea: i. The no status light issue on your Honeywell water heater gas control valve should be solved. The gas will need to disperse, and then you will be ready to try it again. Turn the control knob to the OFF position. If your water heater does not have a digital readout or an automatic reset thermostat, you can test it by turning the knob to the off position and waiting 10 minutes. But make sure youre not pulling it. The simple resolving ways are: The Honeywell water heater knob stuck is another problem you may experience while using this heater. Then, ensure that the reset button of the thermostat is working correctly. Replace the defective one. Tighten the thermal switchs wire lead connection, Ensure your heaters proper gas supply and pressure, Set the thermostat temperature at the proper level and make sure it is not exceeding, Excessive sediment build-up in the heater, Faulty inlet control valve or partially closed valve, Prevent and clean your heaters excessive sediment build-up, Replace the defective inlet control valve, and lousy check valves, Make sure the inlet control valves are open, Control your heaters water pressure fluctuations, Inadequate tank size or too small water heater, Restricted pilot due to carbon deposit build-up in it. You will have to unscrew the thermocouple, from the control valve. If your water heater has a digital readout or an automatic reset thermostat, its likely working. To determine if the igniter is defective, first make sure the igniter is getting voltage. The thermocouple could be damaged and will need to be replaced, or it may just be loose. When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot. Your heaters pilot light stops lighting when it faces restriction due to the carbon deposits build up in it. Then, insert the connectors again and ensure they are fully inserted and tight. To determine if it is simply an issue with the ignition source or your water heater as a whole, first make sure that you check whether or not your water heater is getting power in general because many issues can be caused by a simple power outage that is more serious. The igniter itself when out of the control panel sparks fine but when connected it does not spark at all. > Replace the bad gas control valve, thermostat knob, faulty outer door, weak pilot, and faulty thermostat to ensure proper gas supply to the heater. Save my name, email, and website in this browser for the next time I comment. But before moving to the detailing part, let us walk you through a quick table highlighting all the possible reasons with quick solutions:Probable ReasonsPossible SolutionsThe pilot is not lighting> Clean out the pilot tube.> Relight the pilot following proper instructions.No spark at the igniter> Verify the whiter igniter is firmly inserted into the white or orange connector.> Clean the corroded igniter connection with sandpaper. Use a Multimeter to check the voltage drop across the valve. Another reason for water heater leaks is the tank not being properly sealed. Related Content: Electronic Ignition Water Heater Wont Light? The status light on the gas control valve will not blink if there is an interruption in the gas supply to your water heater. Set the gas control knob to PILOT. Turn the thermostat to its lowest possible setting. We and our partners use cookies to Store and/or access information on a device. Set your thermostat to the desired temperature. Some water heaters use an igniter to ignite the gas. Whatever the problem, first reset your heater and find if resetting could fix your heater issues or not. If it isn't flowing, replace the SmartValve. If the ignition fails, the water will not get hot enough. It ensures a constant flame to light the burner. Using oil will ruin the valve and damage the seal. The best part is- I will also walk you through 3 simple steps to replace the igniter if its at fault.